How do I configure APC Network Management Card network settings? Issue. An APC Network Management Card must be configured with network settings before it can communicate on the network. Once the cards have been configured with an IP address, Subnet Mask, and Default Gateway the cards can be accessed, managed, and controlled from other computers on the network. Operation Manual Smart-UPS. Network Management Card. APC Smart-UPS X 750VA Tower/Rack 120V with bundled network management card (NMC) SMX750-NMC: 0:45. APC Smart-UPS 1500 LCD RM 120V with bundled network management card. Smart-ups was the first network UPS to be Energy. There are multiple configuration options available, outlined below, for each family of Network Management Cards or devices that have embedded versions of these products. Product Line. Devices with an embedded Web/SNMP Card include (but are not limited to): Environmental Monitoring Unit 1 (AP9. TH) Network Management Card 1 (NMC1) - AP9. AP9. 61. 8, AP9. 61. Devices with an embedded Network Management Card 1 include (but are not limited to): Metered/Switched Rack PDUs (AP7. XX, AP7. 9XX), Rack Automatic Transfer Switches (AP7. XX, Environmental Monitoring Units (AP9. Home » spaces » Smart-UPS & Symmetra LX / RM » discussion » General » Smart-UPS 1500 RM with Network Management Card and UPS connection. Smart-UPS 1500 RM with Network. APC Smart-UPS 1500 RM with. Http:// - This short video shows how you can easily set the IP address on your AP9617 APC Network Management Card. APC Smart UPS SMT1500I - Duration: 7:57. MacTalksTech 32,141 views. AP9. 34. 0, Netbotz 2. Network Management Card 2 (NMC2) - AP9. AP9. 63. 0CH, AP9. AP9. 63. 1CH, AP9. We have numerous APC SMART-UPS from 1500 through 7500 all with SNMP Management Cards. Configuration of each UPS is awkward and. It appears that APC Network Management Cards will only allow you to download the config.ini. APC Smart-UPS Battery Backup Power Supply (SMC1500). Output Power Capacity 900 Watts/1500 VA. The 'SMC' line differers from APC's 'SMT' line mainly in that you can't plug in their $220 Network Management Card. Search the VMware Knowledge Base. APC PowerChute Network Shutdown software works in conjunction with the APC UPS Network Management Card to provide a graceful, unattended shutdown of multiple computer systems over a network. Hardware compatibility list. Various (SNMP mode) UPS Network Management Card: snmp-ups: Various (XML/HTTP mode). Smart Winner 750/1000/1500/2000/3000: blazer Uninterruptible Power Supply User Manual. UPS Network Management Card 2 User’s Guide 1 Introduction. IPv6 network configuration provides flexibility to accommodate the user's requirements. Customize the Controllable Outlet Groups and the UPS outlets.9 Network Management Card Settings. 6 Smart-UPS X-Series Operation Configuration. Smart-UPS X-Series Operation. Smart-UPS X-Series Operation. AP9. 63. 5CHDevices with an embedded Network Management Card 2 include (but are not limited to): 2. G Metered/Switched Rack PDUs (AP8. XX, AP8. 6XX, AP8. XX, AP8. 9XX), Certain Audio/Video Network Management Enabled products. Environment. All serial numbers. All firmware revisions (unless otherwise noted)Unconfigured Network Management Card enabled Devices. Network Management Card devices requiring reconfiguration. Cause. A Network Management Card requires TCP/IP settings prior to being accessible accessible via a network. Resolution. If you have a Network Management Card 1: In regards to Network Management Card 1 (AP9. AP9. 61. 8, AP9. 61. Network Management Card 1 (such as a AP7. Apc Smart Ups 1500 Network Management Card Configuration AnalystXX or AP7. 9XX Rack PDU, Environmental Monitoring Unit, etc), there are three available options to configure the Network Management Card (NMC) with it's initial settings: the Wizard, terminal emulation (local/direct connection), and Address Resolution Protocol (ARP). Default boot mode: DHCP/Boot. P - With DHCP Option 4. Vendor Cookie required to accept DHCP Offer. By default, all of APC's Network Management Card 1 based devices are configured for a boot mode of DHCP/BOOTP. If using DHCP, a vendor cookie (DHCP Option 4. If it is not configured on your DHCP server, the card will not accept an IP address. You can use the methods below to configure/access the card if you do not wish to use DHCP/BOOTP. If you have a Network Management Card 2: Default boot mode: DHCP Only - With DHCP Option 4. Vendor Cookie NOT required to accept DHCP Offer. By default, all of APC's Network Management Card 2 based devices (such as a AP8. XXX Next Gen Rack PDU ) with AOS 5. DHCP Only with no vendor cookie required by default. They will obtain an IP address automatically so you may need to refer to your DHCP server to find out what IP address it obtained. All APC devices have a MAC address that begin with 0. C0 B7 which may help while reviewing your DHCP Client List. In order to configure your Network Management Card enabled device, please pick one of the available configuration methods listed below. The wizard must run on a Windows operating system. You can configure the card using the wizard over the network only with v. Prior 3. x versions allow local configuration of the NMC with this program. With the Network Management Card 2 family, the Device IP Configuration Wizard v. You may want to check your DHCP client list for any MAC addresses beginning with 0. C0 B7, which indicates an APC address. In addition, check the card you are trying to configure. Any card with valid IP settings will have a solid green status LED. If using the wizard over the network, please note, the previously unconfigured NMC must be on the same subnet as the computer running the wizard. An alternative method to using the wizard via the network method may be to use a direct network connection between a computer and the NMC you are trying to configure and running the wizard. Ultimately, your computer and the NMC will be on a peer to peer network which will allow for configuration as well. This wizard will also not work with either network management card family if the network management card was previously configured and not in DHCP or BOOTP boot mode. Before using any terminal emulation program, any services using the COM ports must be stopped. For example, if you are running a serial version of APC's Power. Chute software, the APC UPS service must be stopped prior to running the terminal program. Then, follow these instructions: **Please note that if you have the scroll lock on, Hyper. Terminal will not communicate properly with an APC UPS or accessory.**Connect to the UPS/device serial port using the correct APC configuration cable. Part numbers are below for common devices. Please refer to the user's manual if you are not sure or your device is not listed.! WARNING! Configure port settings appropriately for the device you are attached to (reference the user manual for the particular device). Commonly used port settings are as follows: Device COM Port Settings. Most UPSs that have a DB9 serial port. Rack PDU9. 60. 0 bps, 8 data bits, no parity, 1 stop bit, and no flow control. Generation Rack Automatic Transfer Switch (AP7. NMC configuration - refer to user's manual for more information. Generation Rack Automatic Transfer Switch (AP7. XX, excludes AP7. Netbotz 2. 00/Environmental Monitoring (AP9. AP9. 34. 0, AP9. 32. Rack Air Removal Unit. Refer to user's manual. Network Management Card 2 (AP9. AP9. 63. 1) and related accessories require different configuration settings in order to be configured locally. In order to connect to one of these cards, you must use the 9. Tip, Ring Sleeve (TRS) to DB9 cable and connect it directly to the NMC2 into the 2. The tcpip command automatically changes your boot mode to manual once you submit it. It is necessary to issue a reboot command immediately after assigning your manual settings. Text in italics indicates a variable. For each variable, type a numeric value that has the format xxx. It is no longer an option in AOS versions > 5. XFor a video representation of NMC2 configuration via terminal emulation, refer to the video below: Return to Top. Address resolution protocol (ARP) can also be used to configure the NMC. The MAC Address of the NMC is needed for this method of configuration. The MAC address is located on the quality assurance slip that shipped with the NMC, and is also located on a white sticker on the NMC itself. From a computer on the same subnet as the unconfigured NMC, follow these instructions: arp< space> -s< space> < IP address> < space> < MAC Address> You must use the following format for the MAC Address: xx- xx- xx- xx- xx- xx. On Mac OS X specifically: sudo< space> arp< space> -s< space> < IP address> < space> < MAC Address> Next, use Ping with a size of 1. IP address defined by the ARP command. For the IP address defined in the first step, use one of the following: Windows command format: ping< space> < IP address> < space> -l< space> 1. DHCP option 1. 2 uses the devices' host name. As of AOS 5. 1. 5, the default NMC host name will beapc. XXYYZZ, where XXYYZZ represents the last six characters of the MAC Address (enclosed on a slip with the shipped product) of the NMC. It is also available on a sticker on the NMC2 itself. If your network is setup correctly (described below), you will be able to access . At a terminal (or DOS) prompt, ping the NMC using ping apc. XXYYZZ2. In a web browser, access the NMC web interface using http: //apc. XXYYZZNOTE: Tests have shown that even with the network properly configured, the ability to reference devices that support this option is not immediate. In APC tests, it took between 6 and 1. Before proceeding, make sure your NMC2 is installed in the UPS Smart. Slot and is powered, indicated by the status LED on the NMC2. Your UPS display will look similar to one of the following types shown below. Press ESC to bring up the Menu, if not already displayed. In order to access the NMC2 configuration functionality through the UPS LCD, the LCD menu must be put into Advanced Mode. This is accomplished by going into the Configuration menu and changing the Menu Type from Standard to Advanced on the UPS's LCD menu. Upon changing this menu setting, you will be able to configure the UPS NMC2 by going back into the Configuration menu. NMC2 boot mode options available in Configuration Menu. If you choose Manual mode, enter the IP address, subnet mask, and default gateway. DHCP (the NMC2 default AOS v. DHCP & BOOTP models will not require any further configuration beyond accepting the setting. After you've finished, the Network Management Card will reboot within ~1 minute after settings are applied, and the current IP settings will be displayed under the UPS LCD's About menu. Note: If your UPS LCD menu doesn't have the Configure NMC: option after putting the UPS LCD menu in Advanced mode, you may have one or more of the following happening. The NMC2 is not being recognized by the UPS/UPS Smart. Slot. The UPS firmware doesn't support this functionality. Consult the user's guide that came with the UPS or contact your local technical support team with any concerns.
0 Comments
Leave a Reply. |
Details
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |